Highlightoptics provides the laser power measurement devices with air cool. These products could be used for laser manufactures, laser system manufactures and laser laboratories. The laser power sensors cover the range from 10W to 500W. Our Laser Power Meter could also be used as Energy Meters, it can measure with 1Hz, single shot energy.
The application type:
Product model::TP10-HP-19,TP200-HP-25,Lynk-USB-10-HP-19,Lynk-RS232-5-HP-19,Lynk-USB-200-HP-25
Easy to use, high damage threshold Laser Power Meter
Laser power meter is an instrument used to test the power of a continuous laser or the average power of a pulsed laser.
Highlightoptics provides a series Laser Power Meter, such as 10W, 50W, 200W and 500W with air cool. With a compact design and a practical performance, the power meters are easy to use in laser producing and laser equipment area. The power detector have high power damage threshold. For example, the 50 W detector can used CW with 50 W, 150 W in 1.5 Min. It is easy integration and easy installation to equipment.
The power meter display has high resolution color TFT Screen, Two-stage Backlight Square Port USB Interface. It could be used for charging, power supply and data upload.
Laser Power Meter Parameters
Display (Mater):
Model |
Stellar |
Display |
2.8 Inch TFT, 400*240 pixel |
Mode |
Digital display, waveform, curve |
Detector |
TP Series |
Battery |
200mA,Lithiwm ion rechargeable battery |
Memory |
10000 max, Storage time: 1667 hour max |
Power |
5V1A |
Interface |
USB/RS232 |
Dimensions |
170*96*28(mm) |
Material |
Metal |
Weight |
500g |
Detector:
Range |
20mW—500W, Optional |
Resolution |
0.001W—0.1W, Optional |
Response time |
1.5 Sec(50W Laser) |
Threshold |
18KW/cm2 |
Accuracy |
±1.0+1% |
Repeatability |
1% |
Linearity |
1% |
Error range |
±2%,(NIST:±3%) |
Buyer’s guide:
Model |
Rang |
Aperture |
Cooling |
Threshold |
Resolution |
TP10-HP-19 |
20mW—10W |
19mm |
air cool |
15KW/cm2 |
0.001W |
TP50-HP-19 |
20mW—50W |
19mm |
air cool |
15KW/cm2 |
0.01W |
TP200-HP-25 |
0.2W—200W |
25mm |
air cool |
7KW/cm2 |
0.01W |
TP500-HP-25 |
0.5W—500W |
25mm |
air cool |
5KW/cm2 |
0.1W |
TP50-HP-19-E |
50mJ—200J |
19mm |
air cool |
15KW/cm2 |
0.001J |
TP200-HP-25-E |
100mJ—300J |
25mm |
air cool |
7KW/cm2 |
0.001J |
Stellar |
The above probes need to be matched with the meters. |
*With E detector is an Energy meter, can only measure with 1HZ, single shot energy
*50W detector measure 150W in 1.5Min,
USB/RS232 Laser Power Meter
Model |
Rang |
Apertur |
Cooling |
Threshold |
Resolution |
Lynk-USB-10-HP-19 |
20mW—10W |
19mm |
Air cool |
15KW/cm2 |
0.001W |
Lynk-USB-50-HP-19 |
20mW—50W |
19mm |
Air cool |
15KW/cm2 |
0.01W |
Lynk-USB-50-HP-19-B |
20mW—50W |
19mm |
Air cool |
15KW/cm2 |
0.01W |
Lynk-USB-200-HP-25 |
0.2W—200W |
25mm |
Air cool |
7KW/cm2 |
0.01W |
Lynk-USB-500-HP-25 |
0.5W—500W |
25mm |
Air cool |
5KW/cm2 |
0.1W |
10W, 50W Laser power sensor Product features
Detector:
-Quick response (50 W detector : 0 %-95% response time 1.5sec)
- High damage threshold: 11 kW/cm2@40 W
- Wavelength range: 0.19-11μm
- NIST standard
- Compact design
- Connect to Meter
Model |
TP10-HP-19 |
TP50-HP-19 |
Max. Average Power |
10 W |
50 W |
Min. Power |
20 mW |
50 mW |
Power Resolution |
0.001 W |
0.01 W |
Noise Equivalent Power(NEP) |
1 mW |
20 mW |
Response Time |
1 sec |
1.5 sec |
Power Calibration Uncertainty |
± 3% |
± 3% |
Power Linearity(1) |
± 1% |
± 1.5% |
Aperture |
19 mm |
19mm |
Type |
HPB |
HPB |
Absorber Specs |
|
|
Absorber Spectral Range |
0.19 - 11 μm |
0.19 - 11 μm |
Calibration Spectral Range |
0.19 - 2.1 μm, 2.94 μm,9 - 11μm |
0.19 - 2.1 μm, 2.94 μm,9 - 11μm |
Max Power Density(2) |
15kW/cm2@10W |
11kW/cm2@40W |
General Characteristics |
|
|
Cooling |
Conduction(a) |
Conduction(a) |
Weight Dimension |
1.0 kg |
1.5 kg |
Dimension |
65×65×35mm |
65×65×45mm |
Cable length - connector |
2.5 m |
2.5m |
Notes (1). Detector centrally irradiated @50% of useful surface,
(2). Damage thresholds also depend on power level. Please see damage graphs for more details.
200W, 500W Laser power sensor Product features
Detector:
- Quick response (500 W detector : 0 %-95% response time 3sec)
- High damage threshold: 11 kW/cm2@40 W
- Wavelength range: 0.19-11μm
- NIST standard
Model |
TP200-HP-25 |
TP500-HP-25 |
Max. Average Power |
200 W |
500 W |
Min. Power |
0.2 W |
0.5 W |
Power Resolution |
0.1 W |
0.1 W |
Noise Equivalent Power(NEP) |
200 mW |
500 mW |
Response Time |
2 sec |
5 sec |
Power Calibration Uncertainty |
± 3% |
± 3% |
Power Linearity(1) |
± 1% |
± 1.5% |
Aperture |
25 mm |
25mm |
Type |
HPB |
HPB |
Absorber Specs |
|
|
Absorber Spectral Range |
0.19 – 25 μm |
0.19 – 11 μm |
Calibration Spectral Range |
0.19 – 2.1 μm, 2.94μm, 9 – 11 μm |
0.19 – 2.1 μm,2.94μm, 9 – 11μm |
Max Power Density(2) |
5kW/cm2@200W |
3kW/cm2@500W |
General Characteristics |
|
|
Cooling |
Conduction(a) |
Conduction(a) |
Weight Dimension |
1.5 kg |
2.0 kg |
Dimension |
90×90×70 mm |
122×122×118mm |
Cable length - connector |
2.5 m |
2.5 m |
Notes (1). Detector centrally irradiated @50% of useful surface,
(2). Damage thresholds also depend on power level. Please see damage graphs for more details.
USB/RS232 Laser Power Meter Product features
5W,10W,50W Detectors:
- Quick response (50 W detector : 0 %-95% response time 1.5 sec)
- High damage threshold: 11 kW/cm2@40 W
- Wavelength range: 0.19-11μm
- NIST standard
- Compact design
- Connect to Meter
Model |
Lynk-RS232-5-HP-19 |
Lynk-RS232-50-HP-25 |
Max. Average Power |
5 W |
50 W |
Min. Power |
10 mW |
50 Mw |
Power Resolution |
1 mW |
10 mW |
Noise Equivalent Power(NEP) |
500 μW |
20 mW |
Response Time |
0.7 sec |
1.5 sec |
Power Calibration Uncertainty |
± 3% |
± 3% |
Power Linearity(1) |
± 1% |
± 1.5% |
Aperture |
19 mm |
25 mm |
Type |
HPB |
HPB |
Absorber Specs |
|
|
Absorber Spectral Range |
0.19 – 11 μm |
0.19 – 11 μm |
Calibration Spectral Range |
0.19 – 2.1μm,2.94μm,9 – 11μm |
0.19 – 2.1μm,2.94μm,9 – 11μm |
Max Power Density(2) |
18 KW/cm2 |
11KW/cm2@40 W |
General Characteristics |
|
|
Cooling |
Conduction(a) |
Conduction(a) |
Weight Dimension |
0.15 kg |
0.20 kg |
Dimension |
60×60×20 mm |
60×60×20 mm |
Cable length - connector |
2.5 m – USB/1.5m – RS232 |
2.5 m – USB/1.5m – RS232 |
Notes (1). Detector centrally irradiated @50% of useful surface,
(2). Damage thresholds also depend on power level. Please see damage graphs for more details.
Model |
Lynk-USB-10-HP-19 |
Lynk-USB-50-HP-19 |
Max. Average Power |
10 W |
50 W |
Min. Power |
20m W |
50 mw |
Power Resolution |
1 mW |
10 mW |
Noise Equivalent Power(NEP) |
500 μW |
20 mW |
Response Time |
0.7 sec |
1.5 sec |
Power Calibration Uncertainty |
± 3% |
± 3% |
Power Linearity(1) |
± 1% |
± 1.5% |
Aperture |
19 mm |
19 mm |
Type |
HPB |
HPB |
Absorber Specs |
|
|
Absorber Spectral Range |
0.19 – 11 μm |
0.19 – 11 μm |
Calibration Spectral Range |
0.19 – 2.1μm,2.94μm,9 – 11μm |
0.19 – 2.1μm,2.94μm,9 – 11μm |
Max Power Density(2) |
18 KW/cm2@10W |
11 KW/cm2@40 W |
General Characteristics |
|
|
Cooling |
Conduction(a) |
Conduction(a) |
Weight Dimension |
0.15 kg |
0.20 kg |
Dimension |
60×60×45mm |
60×60×45 mm |
Cable length - connector |
2.5 m – USB/1.5m – RS232 |
2.5 m – USB/1.5m – RS232 |
Notes (1). Detector centrally irradiated @50% of useful surface,
(2). Damage thresholds also depend on power level. Please see damage graphs for more details.
200W,500W Detectors:
- Quick response(50 W detector : 0 %-95% response time 1.5 sec)
- High damage threshold: 11 kW/cm2@40 W
- Wavelength range: 0.19-11μm
- NIST standard
- Compact design
- Connect to Meter
Model |
Lynk-USB-200-HP-25 |
Lynk-USB-500-HP-25 |
Max. Average Power |
200 W |
500 W |
Min. Power |
0.2 W |
0.5 w |
Power Resolution |
10 mW |
100 mW |
Noise Equivalent Power(NEP) |
2 mW |
50 mW |
Response Time |
2 sec |
5 sec |
Power Calibration Uncertainty |
± 3% |
± 3% |
Power Linearity(1) |
± 1% |
± 1.5% |
Aperture |
25 mm |
25 mm |
Type |
HPB |
HPB |
Absorber Specs |
|
|
Absorber Spectral Range |
0.19 – 11 μm |
0.19 – 11 μm |
Calibration Spectral Range |
0.19 – 2.1μm,2.94μm,9 – 11μm |
0.19 – 2.1μm,2.94μm,9 – 11μm |
Max Power Density(2) |
4 KW/cm2@200W |
3 KW/cm2@500 W |
General Characteristics |
|
|
Cooling |
Conduction(a) |
Conduction(a) |
Weight Dimension |
1.5 kg |
2.0 kg |
Dimension |
90×90×70mm |
122×122×118 mm |
Cable length - connector |
2.5 m – USB/1.5m – RS232 |
2.5 m – USB/1.5m – RS232 |
Notes (1). Detector centrally irradiated @50% of useful surface.
(2). Damage thresholds also depend on power level. Please see damage graphs for more details.
Product Navigation : Microlens Array Off axis
link : Sina Blog Alibaba163 Blog
Copyright: Highlight Optics Co., Ltd. Address:4A150 No.1 Trading Plaza, China South City, Longgang District, Shenzhen, China
Phone: 0086 0755 89319011 Email: sales@highlightoptics.com