Microlens Array, Off-Axis Parabolic Mirrors,THz lens, TPX lens,Laser Power Meter,Hollow Retroreflectors
中文CartSite Map
Service hotline:+86 0755 84870203
中文English
Service Hotline:+86 0755 84870203

Laser Power Meter

Laser Power Meter

Highlightoptics provides the laser power measurement devices with air cool. These products could be used for laser manufactures, laser system manufactures and laser laboratories. The laser power sensors cover the range from 10W to 500W. Our Laser Power Meter could also be used as Energy Meters, it can measure with 1Hz, single shot energy.

Subordinate to the brand:

The application type:

Product model::TP10-HP-19,TP200-HP-25,Lynk-USB-10-HP-19,Lynk-RS232-5-HP-19,Lynk-USB-200-HP-25

Specifications Add to Cart

 


Easy to use, high damage threshold Laser Power Meter

Laser power meter is an instrument used to test the power of a continuous laser or the average power of a pulsed laser.

Highlightoptics provides a series Laser Power Meter, such as 10W, 50W, 200W and 500W with air cool. With a compact design and a practical performance, the power meters are easy to use in laser producing and laser equipment area. The power detector have high power damage threshold. For example, the 50 W detector can used CW with 50 W, 150 W in 1.5 Min. It is easy integration and easy installation to equipment.

The power meter display has high resolution color TFT Screen, Two-stage Backlight Square Port USB Interface. It could be used for charging, power supply and data upload.



Laser Power Meter Parameters

Display (Mater):

Model

Stellar

Display

2.8 Inch TFT, 400*240 pixel

Mode

Digital display, waveform, curve

Detector

TP Series

Battery

200mA,Lithiwm ion rechargeable battery

Memory

10000 max, Storage time: 1667 hour max

Power

5V1A

Interface

USB/RS232

Dimensions

170*96*28(mm)

Material

Metal

Weight

500g

Detector:

Range

20mW—500W, Optional

Resolution

0.001W—0.1W, Optional

Response time

1.5 Sec(50W Laser)

Threshold

18KW/cm2

Accuracy

±1.0+1

Repeatability

1

Linearity

1

Error range

±2%,(NIST:±3)

Buyer’s guide:

Model

Rang

Aperture

Cooling

Threshold

Resolution

TP10-HP-19

20mW—10W

19mm

air cool

15KW/cm2

0.001W

TP50-HP-19

20mW—50W

19mm

air cool

15KW/cm2

0.01W

TP200-HP-25

0.2W—200W

25mm

air cool

7KW/cm2

0.01W

TP500-HP-25

0.5W—500W

25mm

air cool

5KW/cm2

0.1W

TP50-HP-19-E

50mJ—200J

19mm

air cool

15KW/cm2

0.001J

TP200-HP-25-E

100mJ—300J

25mm

air cool

7KW/cm2

0.001J

Stellar

The above probes need to be matched with the meters.

*With E detector is an Energy meter, can only measure with 1HZ, single shot energy

*50W detector measure 150W in 1.5Min,


USB/RS232 Laser Power Meter

Model

Rang

Apertur

Cooling

Threshold

Resolution

Lynk-USB-10-HP-19

20mW—10W

19mm

Air cool

15KW/cm2

0.001W

Lynk-USB-50-HP-19

20mW—50W

19mm

Air cool

15KW/cm2

0.01W

Lynk-USB-50-HP-19-B

20mW—50W

19mm

Air cool

15KW/cm2

0.01W

Lynk-USB-200-HP-25

0.2W—200W

25mm

Air cool

7KW/cm2

0.01W

Lynk-USB-500-HP-25

0.5W—500W

25mm

Air cool

5KW/cm2

0.1W


10W, 50W Laser power sensor Product features

Detector:

-Quick response (50 W detector : 0 %-95 response time 1.5sec)

- High damage threshold: 11 kW/cm2@40 W

- Wavelength range: 0.19-11μm

- NIST standard

- Compact design

- Connect to Meter


Model

TP10-HP-19

TP50-HP-19

Max. Average Power

10 W

50 W

Min. Power

20 mW

50 mW

Power Resolution

0.001 W

0.01 W

Noise Equivalent Power(NEP)

1 mW

20 mW

Response Time

1 sec

1.5 sec

Power Calibration Uncertainty

± 3

± 3

Power Linearity(1)

± 1

± 1.5

Aperture

19 mm

19mm

Type

HPB

HPB

Absorber Specs

Absorber Spectral Range

0.19 - 11 μm

0.19 - 11 μm

Calibration Spectral Range

0.19 - 2.1 μm, 2.94 μm,9 - 11μm

0.19 - 2.1 μm, 2.94 μm,9 - 11μm

Max Power Density(2)

15kW/cm2@10W

11kW/cm2@40W

General Characteristics

Cooling

Conduction(a)

Conduction(a)

Weight Dimension

1.0 kg

1.5 kg

Dimension

65×65×35mm

65×65×45mm

Cable length - connector

2.5 m

2.5m

Notes (1). Detector centrally irradiated @50% of useful surface,

(2). Damage thresholds also depend on power level. Please see damage graphs for more details.


200W, 500W Laser power sensor Product features

Detector:

- Quick response (500 W detector : 0 %-95 response time 3sec)

- High damage threshold: 11 kW/cm2@40 W

- Wavelength range: 0.19-11μm

- NIST standard


Model

TP200-HP-25

TP500-HP-25

Max. Average Power

200 W

500 W

Min. Power

0.2 W

0.5 W

Power Resolution

0.1 W

0.1 W

Noise Equivalent Power(NEP)

200 mW

500 mW

Response Time

2 sec

5 sec

Power Calibration Uncertainty

± 3

± 3

Power Linearity(1)

± 1

± 1.5

Aperture

25 mm

25mm

Type

HPB

HPB

Absorber Specs

Absorber Spectral Range

0.19 – 25 μm

0.19 – 11 μm

Calibration Spectral Range

0.19 – 2.1 μm, 2.94μm, 9 – 11 μm

0.19 – 2.1 μm,2.94μm, 9 – 11μm

Max Power Density(2)

5kW/cm2@200W

3kW/cm2@500W

General Characteristics

Cooling

Conduction(a)

Conduction(a)

Weight Dimension

1.5 kg

2.0 kg

Dimension

90×90×70 mm

122×122×118mm

Cable length - connector

2.5 m

2.5 m

Notes (1). Detector centrally irradiated @50% of useful surface,

(2). Damage thresholds also depend on power level. Please see damage graphs for more details.


USB/RS232 Laser Power Meter Product features

5W,10W,50W Detectors:

- Quick response (50 W detector : 0 %-95 response time 1.5 sec)

- High damage threshold: 11 kW/cm2@40 W

- Wavelength range: 0.19-11μm

- NIST standard

- Compact design

- Connect to Meter


Model

Lynk-RS232-5-HP-19

Lynk-RS232-50-HP-25

Max. Average Power

5 W

50 W

Min. Power

10 mW

50 Mw

Power Resolution

1 mW

10 mW

Noise Equivalent Power(NEP)

500 μW

20 mW

Response Time

0.7 sec

1.5 sec

Power Calibration Uncertainty

± 3

± 3

Power Linearity(1)

± 1

± 1.5

Aperture

19 mm

25 mm

Type

HPB

HPB

Absorber Specs

Absorber Spectral Range

0.19 – 11 μm

0.19 – 11 μm

Calibration Spectral Range

0.19 – 2.1μm2.94μm9 – 11μm

0.19 – 2.1μm,2.94μm,9 – 11μm

Max Power Density(2)

18 KW/cm2

11KW/cm2@40 W

General Characteristics

Cooling

Conduction(a)

Conduction(a)

Weight Dimension

0.15 kg

0.20 kg

Dimension

60×60×20 mm

60×60×20 mm

Cable length - connector

2.5 m – USB/1.5m – RS232

2.5 m – USB/1.5m – RS232

Notes (1). Detector centrally irradiated @50% of useful surface,

(2). Damage thresholds also depend on power level. Please see damage graphs for more details.


Model

Lynk-USB-10-HP-19

Lynk-USB-50-HP-19

Max. Average Power

10 W

50 W

Min. Power

20m W

50 mw

Power Resolution

1 mW

10 mW

Noise Equivalent Power(NEP)

500 μW

20 mW

Response Time

0.7 sec

1.5 sec

Power Calibration Uncertainty

± 3

± 3

Power Linearity(1)

± 1

± 1.5

Aperture

19 mm

19 mm

Type

HPB

HPB

Absorber Specs

Absorber Spectral Range

0.19 – 11 μm

0.19 – 11 μm

Calibration Spectral Range

0.19 – 2.1μm2.94μm9 – 11μm

0.19 – 2.1μm,2.94μm,9 – 11μm

Max Power Density(2)

18 KW/cm2@10W

11 KW/cm2@40 W

General Characteristics

Cooling

Conduction(a)

Conduction(a)

Weight Dimension

0.15 kg

0.20 kg

Dimension

60×60×45mm

60×60×45 mm

Cable length - connector

2.5 m – USB/1.5m – RS232

2.5 m – USB/1.5m – RS232

Notes (1). Detector centrally irradiated @50% of useful surface,

(2). Damage thresholds also depend on power level. Please see damage graphs for more details.


200W,500W Detectors

- Quick response(50 W detector : 0 %-95 response time 1.5 sec)

- High damage threshold: 11 kW/cm2@40 W

- Wavelength range: 0.19-11μm

- NIST standard

- Compact design

- Connect to Meter



Model

Lynk-USB-200-HP-25

Lynk-USB-500-HP-25

Max. Average Power

200 W

500 W

Min. Power

0.2 W

0.5 w

Power Resolution

10 mW

100 mW

Noise Equivalent Power(NEP)

2 mW

50 mW

Response Time

2 sec

5 sec

Power Calibration Uncertainty

± 3

± 3

Power Linearity(1)

± 1

± 1.5

Aperture

25 mm

25 mm

Type

HPB

HPB

Absorber Specs

Absorber Spectral Range

0.19 – 11 μm

0.19 – 11 μm

Calibration Spectral Range

0.19 – 2.1μm2.94μm9 – 11μm

0.19 – 2.1μm,2.94μm,9 – 11μm

Max Power Density(2)

4 KW/cm2@200W

3 KW/cm2@500 W

General Characteristics

Cooling

Conduction(a)

Conduction(a)

Weight Dimension

1.5 kg

2.0 kg

Dimension

90×90×70mm

122×122×118 mm

Cable length - connector

2.5 m – USB/1.5m – RS232

2.5 m – USB/1.5m – RS232

Notes  (1). Detector centrally irradiated @50% of useful surface.

(2). Damage thresholds also depend on power level. Please see damage graphs for more details.

Inquiry form

With * is required!
*The contact:
*email:
*company name:
*phone number:
message:
*Verification code:
Verification code

Related applications

Related products

Product Navigation : Microlens Array Off axis

link : Sina Blog Alibaba163 Blog

Copyright: Highlight Optics Co., Ltd. Address:4A150 No.1 Trading Plaza, China South City, Longgang District, Shenzhen, China
Phone: 0086 0755 89319011 Email: sales@highlightoptics.com